| Error Codes | Solution |
|---|---|
| F1 | Temperature stop fault. The temperature rise is less than 5°C in ten minutes. Check: Element, thermistor, water level, circulation pump and control unit, wiring. |
| F2 | Overfilling. Too much water in the machine (pressure sensor) or float activated. Check: Drain pump (blockage in hoses), flow sensor, inlet valve, leakage, wiring. |
| F3 | Thermistor fault. Interruption or >80°C. The programme exits from the heating stage and continues in the process. Indication only in the service menu. Check: Thermistor, control unit. |
| F4 | Water intake fault. < 80 pulses within 60 seconds or correct number of pulses is not achieved within 255 seconds. Programme interrupted. Check: Water supply, flow sensor, inlet valve, wiring. |
| F5 | Valve leakage. > 80 pulses detected when the inlet valve is deactivated. Certain models attempt to remedy the leak first. Any programme in progress is interrupted (drain pump activated). Check: Leakage through inlet valve, flow sensor. |
| F6 | Pressure sensor fault. Output signal > 4.8V. The programme continues. Indication only in the service menu. Check: Pressure sensor, control unit and wiring. |
| F7 | Pumping out fault. Water not evacuated after 120 seconds’ pumping out. Programme interrupted. Check: Drain pump, hoses, installation of drain hose, control unit and wiring. |
| F8 | Blocked filter. The pressure sensor senses excessively low pressure during the final rinse. Indication after end of programme. Check: Filter, sump (pressure chamber), pressure sensor. |
| F9 | Circulation fault. The pressure sensor senses excessively low pressure (e.g. no water in the machine) or excessively high pressure (e.g. the circulation pump is defective). Check: Circulation pump, filter, water level, pressure chamber and pressure sensor. |
| F10 | Overfilling. Check Drain pump (blocked hose), flow meter, inlet valve, leaks and cables. |
| F11 | Water outlet fault. Check Drain pump, hoses, drain hose fittings, control unit and cables. Also check whether filter is blocked. |
| F12 | Water inlet fault. Check Water inlet, flow meter, inlet valve and cables. |
| F40 | Inlet valve leakage. Check Leak through inlet valve and flow meter |
| F41 | Temp stop fault. Check Element, thermistor, water level, circulation pump, control unit and cables. |
| F42 | Thermistor fault. Check Thermistor, plugs, wire harness, and control unit. |
| F43 | Pressure sensor fault. Check Pressure sensor, control unit and cables. |
| F44 | Turbidity sensor fault. Check Water quality, filters, turbidity sensor and drain system. |
| F45 | Spray arm diverter fault. Check Spray arm diverter (functioning gearbox, switches and cables). |
| F52 | Water level fault |
| F54 | Overfilling water 2. Turn off the water supply valve. |
| F56 | Circ. pump fault. |
| FA | Turbidity sensor fault. Indication only in the service menu. The machine assumes high turbidity for “choice of route” in the automatic programme. Check: Water quality, filter, turbidity sensor, drain system. |
| FB | Spray arm divider fault. Position contact is continuously closed or open. The programme proceeds. Indication only in the service menu. Check: Spray arm divider (function of gearbox, contacts and wiring). |
| L6 | Rinse aid indication |
| L7 | Door open/Close door |
| Close the door | The door is open. Close the door. |
| Temp stop fault | Temperature increase less than 5°C (41°F) in ten minutes. Program continues with the process. Only indicated in service menu. |
| Overfilling | Overfilling. Too much water in the machine (pressure sensor) or float activated. If the water has not been emptied within 60 seconds, the program stops (drain pump activated). |
| Thermistor fault | Communication between the thermistor and control unit has stopped or the thermistor is reporting temperatures greater than 80°C (176°F). Program continues with the process. Only indicated in service menu. |
| Water inlet fault | < 80 pulses within 60 seconds or correct number of pulses not achieved within 255 seconds. Program stops. |
| Inlet valve leakage | Water intake detected when inlet valve deactivated in program sequence or standby. In this case the machine attempts to close the valve by opening it for 2 seconds and then closing it again. If water flow through the valve is still detected any current program is stopped (drain pump activated). |
| Pressure sensor fault | Output signal > 4.8 V. The program continues. Only indicated in service menu. |
| Water outlet fault | Water not drained after 120 seconds draining. Program stops. |
| Turbidity sensor fault | Only indicated in service menu. The machine assumes high turbidity in case of “uncertainty” in the auto program. |
| Diverter fault | Position switch always closed or open. The program continues. Only indicated in service menu. |
| Humidity sensor fault | “Humidity sensor fault” (only in service menu) Check Humidity sensor, cables, fan, damper and Wax motor. |
| Clean filter | The display indicates “Clean filter” automatically after every 300 cycles. |
Total Reset
To reset the machine to its factory settings.
- Turn off the main power switch (S5).
- Wait at least 5 seconds.
- Press and hold the program and menu buttons (S1 and S4).
- Switch on the main power switch (S5).
- Release the program and menu buttons (S1 and S4).
Asko Dishwasher Troubleshooting

| Problem | Possible causes |
|---|---|
| The dishes are not clean. | The spray arms do not rotate. |
| Old detergent. Detergent is a perishable product. | |
| Incorrect detergent dosage. | |
| Dishwashing program too weak. | |
| Dishes loaded incorrectly. | |
| Glasses and cups have toppled over during the program. | |
| The filter is not correctly fitted. | |
| Spots or films on the dishes. | Incorrect rinse aid dosage setting. |
| The dishes have a sticky white/blue film. | Rinse aid dosage setting too high. |
| Spots on stainless steel or silver. | Some foodstuffs, such as mustard, mayonnaise, lemon, vinegar, salt and dressings, can mark stainless steel if left for too long. |
| Spots left after washing. | Lipstick and tea can be difficult to wash off. Use a detergent with a bleaching agent. |
| Rattling sound when dishwashing. | The dishes are not correctly placed or the spray arms are not rotating. Check that the dishes are placed securely. Spin the spray arms to make sure they can rotate. |
| The dishwasher does not start. | The Start/Stop start button has not been pressed for long enough. |
| The door is not properly closed. | |
| A fuse/circuit breaker has been tripped. | |
| The plug is not plugged into the wall socket. | |
| The water tap is turned off. | |
| Overflow/leaks | |
| Check that the Delayed start option has not been selected. | |
| 1 minute appears in the display | The program is taking longer than estimated. None, next time the program is run the corrected time will be displayed. |
| Water remains in the dishwasher | Blocked drainage hose. |
| Kink in drainage hose. | |
| The filters are blocked. | |
| The filter is not locked in completely. | |
| Debris in the drainage pump. | |
| Bad odour in dishwasher. | Dirt around the seals and in corners. |
| Low temperature programs have been selected for a prolonged period. | |
| The dishes are not dry enough. | Drying power too low. |
| The dishwasher is not fully loaded. | |
| Rinse aid needs topping up or dosage is set too low. | |
| Cannot close door. | The baskets are not correctly positioned. |
| The touch buttons do not react when pressed. | Dirt on the touch buttons. |

Comments
Post a Comment